Browse all practice questions for the HVAC EPA Type I Practice Test. Search by topic, open any question and review its full explanation, then test yourself in the practice quiz.

HVAC EPA Type I Practice Test course image
All questions

These questions are part of the practice quiz. Start practicing

  • A small appliance is defined in EPA rules as having which characteristic?
  • What basic safety steps should you take before servicing a Type I appliance?
  • EPA regulations require the capture of at least 80% of the refrigerant from a small appliance with a non-operating compressor when the technician is using:
  • Which statement describes the EPA's small appliance definition?
  • What must be absent for the 300 psig reading?
  • After the refrigerant has been recovered, which of the following can be used to flush the system?
  • On a system with an operating compressor, recovery equipment must be capable of recovering
  • To achieve the 300 psig reading for a half-full R-410A cylinder at 90°F, which condition must be present?
  • If regulations change after a technician becomes certified, who must comply with the new rules?
  • On a small appliance with an operating compressor that has a completely plugged capillary tube, what is the minimum number of access valves that are needed to evacuate the refrigerant?
  • Self-contained or active recovery equipment
  • Which connections on a manifold gauge set are used for Type I charging and recovery?
  • A refrigerant that can be used as a direct service 'drop-in' substitute for R-22 in a small appliance is:
  • System-dependent recovery methods may only be used on appliances containing how much refrigerant?
  • A Very-High-Pressure appliance is one that uses a refrigerant with a liquid phase saturation pressure above 355 psia at 104F. This definition includes but is not limited to appliances using which of the refrigerants listed below:
  • Technician certification required for sealed-system service on small appliances?
  • In general, how does increasing temperature affect the pressure of a fixed amount of refrigerant vapor in a sealed cylinder?
  • Why is mixing refrigerants dangerous?
  • Which are signs that recovered refrigerant might be contaminated?
  • What is the EPA-defined maximum refrigerant charge for a small appliance?
  • After recovering refrigerant, which action is compliant with typical EPA Type I practices?
  • Which statement about reclamation refrigerant is true?
  • A recovery cylinder which is half full of recovered R-500 at normal room temperature (about 75F), in the absence of non-condensables, will be pressurized to:
  • What does ARI 740-1993 establish in relation to refrigerant recovery for small appliances?
  • Which statement about Type I charging methods is true?
  • The EPA regulation that requires a self-contained recovery machine at the place of business has an exception for which group?
  • When you connect your service manifold to check system pressures, which practice should you follow to minimize releases?
  • ARI 740-1993 relates to which aspect of refrigerant recovery?
  • Which of the following statements correctly describes responsibility when EPA regulations change after certification?
  • What is ARI 700?
  • What performance standard must modern recovery devices meet when recovering refrigerant from small appliances?
  • Which HC refrigerant is allowed for use in NEW Domestic Small Appliances?
  • The threshold liquid phase saturation pressure that defines Very-High-Pressure appliances is above what value at 104F?
  • The Very-High-Pressure appliance category includes appliances using which of the following refrigerants?
  • When recovering refrigerant from a frost-free refrigerator, what step should be taken to handle possible trapped liquid?
  • What is the recommended process if unknown refrigerant is encountered during retrofit?
  • A recovery cylinder which is half full of recovered R-12 at normal room temperature (about 75F), in the absence of non-condensables, will be pressurized to:
  • If you suspect refrigerant contamination, what should you do?
  • During charging cylinder filling with regulated refrigerant, the vapor vented from the top of the cylinder should be recovered.
  • When a system is in deep vacuum, what should you do?
  • The sale of CFC and HCFC refrigerants is restricted to technicians who are what?
  • Portable refillable tanks used to ship recovered refrigerants must meet which standard?
  • Which refrigerant is mentioned as being in a recovered cylinder?
  • What is the main purpose of Type I practice tests?
  • How should recovered refrigerant cylinders be labeled and stored?
  • After installing and opening a piercing access valve, if the system pressure is _____ do not begin the recovery procedure.
  • Noncondensable gases inside a recovery cylinder are defined as gases that do what under ambient conditions?
  • After recovering refrigerant, what must you do with the recovered material?
  • When pressurizing a system with nitrogen you should
  • Why is cross-contamination between refrigerants in storage a concern?
  • Which statement correctly describes the environmental protection goal of Type I refrigerant handling?
  • System-dependent or passive recovery equipment captures refrigerant into what kind of container?
  • If after installing a fitting for recovering the appliance refrigerant you find that the system pressure is 0 psig, what is required?
  • Which statement best describes the scope of EPA's 608 Type I certification?
  • To avoid drawing liquid refrigerant into a self-contained (active) recovery device that cannot handle liquid, from which side of the system should vapor be drawn?
  • What is the proper sequence when handling unknown refrigerants in the field?
  • Which of the following is true about non-condensables?
  • True or false: Non-condensables in a recovery cylinder can cause the pressure to be higher than expected at a given temperature.
  • When R-500 is recovered from an appliance, which statement is correct?
  • How does moisture affect a refrigerant system?
  • A small appliance is defined by EPA as
  • How does recycling differ from reclamation?
  • If a Schrader valve core is damaged, what is the recommended action?
  • A recovery cylinder that is half full of recovered R-22 at about 75 °F, in the absence of non-condensables, will be pressurized to approximately how many psi?
  • Which hazard class designation is used for non-flammable gases?
  • What can a pressure reading along with a temperature reading indicate in a refrigerant recovery cylinder?
  • Which of the following should be recovered with current EPA-approved recovery devices?
  • A passive system-dependent recovery device for small appliances is designed to capture refrigerant in what type of container?
  • Which statement best describes service on domestic refrigerators with refrigeration systems?
  • In the event of a large release of R-12 or R-22 in a contained area, which safety measure is required?
  • Anyone who recovers refrigeration during maintenance, service or repair of small appliances must be certified as either a Universal Tech or a:
  • Technicians with a Type I small appliance certification are certified to recover refrigerant during the maintenance, service or repair of:
  • The EPA definition of a small appliance includes which of the following?
  • Which statement describes recovery unit flexibility with respect to achieving 80% capture?
  • Why is a technician required to be EPA 608 certified to service small appliances?
  • When should a filter-drier be replaced?
  • What is the purpose of pulling a vacuum after evacuating a system?
  • Who must hold EPA 608 certification to service small appliances?
  • What certification is required to legally work on refrigerants in the U.S.?
  • Recovery equipment used for the service or repair of small appliances must be certified by an EPA-approved laboratory if the equipment was manufactured after which date?
  • Equipment manufactured after November 15, 1993 used to recover refrigerant from small appliances prior to disposal must meet which recovery percentage requirements?
  • Which two readings are used to assess whether non-condensables are present in a recovery cylinder?
  • If a unit leaks and the repair cannot be completed immediately, what should be done with the refrigerant?
  • A passive recovery device for small appliances captures refrigerant in what kind of container?
  • After servicing, what method is commonly used to verify there are no leaks after charging?
  • If R-12 or R-22 are exposed to high temperatures, what can they decompose to form?
  • Recovery equipment for small appliances must be certified if manufactured after which date?
  • If nitrogen is used to pressurize or blow debris out of a system, what is allowed regarding the nitrogen?
  • Type I Certification is required for;
  • Which of the following refrigerants is allowed in NEW Domestic Small Appliances?
  • Which of the following is an example of a non-condensable?
  • When servicing equipment containing regulated refrigerants, you should use what kind of recovery devices?
  • Who is legally allowed to purchase refrigerant according to EPA rule references?
  • What is the best practice when dealing with unknown refrigerants in the field?
  • If the refrigerant type cannot be identified, how should it be treated?
  • Which statement best reflects EPA's rule on self-contained recovery equipment?
  • How should unknown refrigerant be addressed in a retrofit or service project?
  • What type of leak detector is acceptable for Type I systems?
  • If a system is purged or debris is blown from a system using nitrogen, which form of nitrogen is recommended?
  • Exposure of R-12 or R-22 to high heat can produce acids. Which acids are formed?
  • Which action is required by the EPA during service to handle refrigerants?
  • When using a passive system-dependent recovery process, you should access both the high and low side of the system for the refrigerant recovery if _____________.
  • Which of the following are part of the EPA's recommended safe work practices?
  • Small appliances in recreational vehicles may use refrigerants such as Ammonia, Hydrogen, and water. These refrigerants
  • Withdrawal of vapor from the high side is preferred because it prevents entering the recovery device of what?
  • Which statement is true about handling refrigerants today in Type I service?
  • What is the purpose of ARI 740-1993 in refrigerant recovery?
  • To what vacuum level should you evacuate a Type I system before charging?
  • When using a passive system-dependent recovery method on an appliance with an operating compressor, what action should be taken?
  • Recovery equipment must be
  • Hazard class 2.2 is associated with which type of materials?
  • When using a system-dependent recovery system on an appliance that has a non-operating compressor, the technician should
  • What is the significance of color-coding refrigerant cylinders?
  • Which statement best describes the effect of a dirty or degraded filter-drier?
  • When using nitrogen, the nitrogen tank should be equipped with a regulator
  • The service aperture or other device used when adding or removing refrigerant from an appliance is typically accessed through what component on small appliances?
  • Which statement correctly describes the refrigerant charge limit for a small appliance?
  • With a non-operating system compressor, recovery equipment must be capable of recovering
  • How does the EPA define a 'small appliance' for Type I?
  • What is the typical outcome if you overcharge a small Type I appliance?
  • When using nitrogen, the nitrogen tank should always be equipped with a:
  • If a pungent odor is detected during system recovery and/or repair, which of the following is most likely?
  • A strong odor during refrigerant recovery indicates what?
  • When servicing a small appliance with a leak, which statement best describes the repair requirement?
  • Which of the following is not a Type I appliance?
  • What is the typical lubricant in R-22 systems, and what is common for R-134a systems?
  • Which statement about venting refrigerant is correct?
  • During maintenance, what certifications are commonly recognized for refrigerant recovery?
  • Applying heat, with a heat gun, to the compressor
  • What is the purpose of service ports on refrigerant lines?
  • What are the three paths for handling recovered refrigerant?
  • How should you handle R-12 or R-22 in Type I service today?
  • Which statement correctly describes the EPA's stance on leaks from Type 1 equipment?
  • A refrigerant that can be used as a direct service 'drop-in' substitute for R-22 in a small appliance is:
  • What is the correct sequence when repairing a leak and recharging a Type I system?
  • According to the EPA, which recovery equipment maintenance practice should be performed on a regular basis?
  • Type I Certification is required for individuals handling refrigerant during maintenance, service, or repair of small appliances.
  • What should you do if the refrigerant type on a unit's label is missing or unreadable?
  • Which entity governs the standard for reclaimed refrigerants purity used in recovery and reclamation processes?
  • Which statement best describes the obligation when environmental regulations are amended after certification?
  • ARI 700 is the standard for what?
  • What type of documentation is typically required when handling refrigerants?
  • When using equipment that has Schrader valves, which statements are considered critical?
  • Which condition can contribute to excessive high-side pressure in a self-contained recovery device?
  • When transporting refrigerants, DOT 49 CFR requires which information to be recorded on shipping papers for hazard class 2.2?
  • When recovering refrigerant into a non-pressurized container from a refrigerator with an improper compressor, what is described as necessary?
  • Why must R-500 be recovered into its own clearly marked vessel?
  • The sale of refrigerant is restricted to which group?
  • When purging or blowing debris from a system, which form of nitrogen should be used?
  • What is a reason to perform post-charge leak checks?
  • What should you do with refrigerant cylinders after use?
  • Why should recovered cylinders be stored upright?
  • What is a common consequence of failing to replace a dirty or degraded filter-drier?
  • What is subcooling in the context of Type I charging?
  • Which statement is true regarding refrigerant leaks on small appliances?
  • Which refrigerant is most commonly used as a replacement for R-12 in new household refrigerators?
  • Which statement about mixing refrigerants is correct?
  • When using a graduated charging cylinder, what must be done with any refrigerant vented from the cylinder?
  • A standard vacuum pump designed for evacuation and dehydration can never be used as a recovery device in combination with a pressurized container.
  • For small appliances, the service port typically is:
  • What refrigerant is described in the scenario?
  • For hazard class 2.2 shipments, what information must appear on shipping papers?
  • Where should recovered refrigerant cylinders be returned after use?
  • Which oil is commonly used with R-134a in Type I appliances?
  • Which practice helps prevent cross-contamination when storing refrigerants?
  • Which statement about recycling is true?
  • When filling a charging cylinder with a regulated refrigerant, what must be recovered?
  • Why is the system nameplate important during service?
  • Which equipment falls under EPA Type I?
  • Which component is used as the installation location for a piercing-type access valve on a small appliance?
  • If you install an access fitting onto a sealed refrigerant system, what procedure should be performed before starting recovery?
  • Why is it important to allow the temperature of the refrigerant to stabilize at room temperature before taking a pressure reading when checking for noncondensable gases inside a recovery cylinder?
  • When using a system-dependent recovery system on an appliance with a non-operating compressor, where should access fittings be placed?
  • Which statement about recovery equipment certification is true?
  • What is the maximum allowable factory charge or refrigerant for Type I appliances?
  • Under EPA Section 608, which refrigerant must be recovered with equipment currently regulated by the certification requirements?
  • What should you check after recharging for leaks and proper operation?
  • Which option best defines the term superheat as used in Type I charging?
  • In a frost-free refrigerator, the defrost heater is used to vaporize trapped liquid so that the refrigerant is in which state for recovery?
  • Recovering multiple refrigerants in the same cylinder has what effect on the reclaimed material?
  • A standard vacuum pump designed specifically for evacuation and dehydration can be used as a recovery device only when it is used with what kind of container?
  • Technicians who perform sealed-system service on small appliances must have
  • Which action should be avoided when dealing with contaminated refrigerant?
  • What is the purpose of evacuating a Type I system after repairing a leak?
  • If a large leak of refrigerant occurs in an enclosed area and no self-contained breathing apparatus is available, then the technician should:
  • Which of the following describes proper labeling for recovered refrigerant cylinders?
  • What is the EPA rule regarding venting during service?
  • For which appliance would it be permissible to use a passive recovery device for refrigerant recovery?
  • Low loss fittings are used to connect the recovery device to an appliance and are designed to do what when disconnected?
  • What are the three main refrigerant-handling categories, and which one does Type I primarily use?
  • What practice minimizes refrigerant release when connecting service lines?
  • Piercing-type valves should only be used on which tubing materials?
  • What is the primary charging method for Type I appliances when allowed by the manufacturer?
  • Small appliances are equipped with a straight piece of tubing (process stub) that is used
  • Are you allowed to vent refrigerant to the atmosphere after service?
  • If a recovery tank contains a mixture of refrigerants, what action might a reclamation processing plant take?
  • System-dependent or passive recovery equipment is characterized by what behavior?
  • What happens if multiple refrigerants are recovered in a single cylinder?
  • Non-condensables in a refrigerant cylinder are best described as which?
  • A standard vacuum pump designed for evacuation and dehydration can be used as a recovery device only when used with what configuration?
  • If a strong odor is detected during refrigerant recovery, what is the likely condition?
  • Which refrigerant handling practice helps protect the environment during service?
  • When recovering refrigerant from a household refrigerator whose compressor does not run, it is recommended that low and high side access valves be installed because _____________:
  • How often must the EPA Section 608 certification be renewed?
  • Installing low and high side access valves on a non-operating refrigerator is recommended because it can:
  • Which of the following indicates a potential problem after recharging a Type I system?
  • A refrigerant that can be used as a direct service 'drop-in' substitute for R-12 in a small appliance is:
  • Define superheat in the context of Type I charging.
  • What is the maximum refrigerant charge for appliances covered by EPA Type I certification?
  • When using ______, it is essential to take extra measures (such as heating/striking), to help release trapped refrigerant from the compressor oil.
  • At high temperatures, R-12 and R-22 can decompose to form which gas?
  • Why should solderless piercing valves not remain installed on refrigerant systems after repairs?
  • Large spills of refrigerants can cause suffocation because:
  • Which refrigerants are associated with ozone depletion and commonly found in Type I equipment?
  • What micron level is typically targeted during a vacuum for a Type I service?
  • What unit is used to measure vacuum level in Type I service?
  • Recovery devices that were manufactured before November 15, 1993 and are used for recovery of refrigerant from small appliances must be capable of:
  • A recovery cylinder half full of recovered R-410A at 90°F, in the absence of non-condensables, will be pressurized to approximately how many psig?
  • What equipment is required to remove refrigerant from Type I appliances?
  • Prior to shipping any used refrigerant it is necessary to:
  • Before beginning a refrigerant recovery procedure, what is ALWAYS necessary to determine?
  • When using a system-dependent recovery system on an appliance with an operating compressor, the technician should
  • Which of the following best describes the 300 psig reading scenario?
  • Applying heat to the compressor during recovery
  • Why is mixing refrigerants generally avoided?